Insulin Purification
TSKgel SP-3PW (30) resin was developed as a higher resolving and higher capacity resin for insulin purification.
Selectivity comparison
|
|
Resins: |
A. TSKgel SP-3PW (30)
B. SOURCE 30S
C. TSKgel SP-5PW (30)
|
Column size: |
7.5 mm ID × 7.5 cm |
Mobile phase: |
Buffer A: 0.02 mol/L sodium citrate buffer, pH 3.2 + ethanol = 8/2 (v/v)
Buffer B: 0.02 mol/L sodium citrate buffer, pH 3.2 + 1.0 mol/L NaCl/ethanol = 8/2 (v/v)
|
Gradient: |
60 min linear gradient from buffer A to buffer B |
Flow rate: |
136 cm/hr (1.0 mL/min) |
Detection: |
UV @ 280 nm |
Temperature: |
ambient |
Samples: |
1. trypsinogen
2. insulin
3. lysozyme |
Sample vol.: |
100 µL (0.5 g/L each) |
|
Dynamic binding capacity comparison
Resin |
TSKgel SP-3PW (30) |
TSKgel SP-5PW (30) |
SOURCE 30S |
Matrix |
polymethacrylate |
polymethacrylate |
polystyrene
divinylbenzene |
Particle
size
|
30 µm |
30 µm |
30 µm |
Insulin
capacity |
49 g/L |
24 g/L |
45 g/L |
Pore
size
|
25 nm |
100 nm |
NR |
|
|
Dynamic binding capacities were determined at 10% breakthrough.
Column size: |
4.6 mm ID × 7.5 cm |
Mobile phase: |
gradient elution with 1-propanol by acidic buffer, pH 3.0 containing neutral salt
|
Flow rate: |
270 cm/hr (0.75 mL/min) |
Sample: |
recombinant insulin (7.2 g/L) |
|
For additional applications, please see our applications database.