Products

HPLC Columns

TSKgel Alpha-3000

The TSKgel Alpha-3000 column is packed with rigid, porous, polymer beads which show minimal shrinkage or swelling in polar organic solvents (methanol, acetonitrile, DMSO, isopropanol, THF, and HFIP).  This column is stable in a wide variety of organic solvents at concentrations up to 100%.

The main application area for the TSKgel Alpha-3000 column is the analyses of polymers that are soluble in polar organic solvents up to 100,000 Da. Examples include cellulose derivatives, polyimide, and sodium dodecylsulfate (all in 10 mmol/L LiBr in DMF), cleansing gel in methanol, and degree of saponification of polyvinylalcohol in hexafluoroisopropanol (HFIP).


 
P/NDescriptionParticle Size Housing MaterialID (mm)Length (cm)Price ($) 
0018340TSKgel Alpha-30007Stainless Steel7.8302,074
          

Product Attributes

Matrix: hydrophilic methacrylate
Particle size (mean): 7 µm
Pore size (mean): 15 nm
Exclusion limits
    PEO in H2O: 9 × 104
    PS in DMF with
    10 mmol/L LiBr:
1 × 105
    PEG in MeOH with
    10 mmol/L LiBr:
6 × 104

 

 
 

 

Polyethylene Oxide, Polyethylene Glycol, and Polystyrene Calibration Curves

SEC_Alpha-Calibration-Fig48.png

Columns: TSKgel Alpha columns,
7.8 mm ID × 30 cm
Mobile phase: A. H2O
B. MeOH with 10 mmol/L LiBr
C. DMF with 10 mmol/L LiBr
Flow rate: 1.0 mL/min
Detection: RI
Temperature: A. 25°C  B. 25°C  C. 40°C
Samples: A, B. polyethylene glycol (PEG) and
polyethylene oxide (PEO) standards
C. polystyrene (PS) standards

    

Analysis of Polyvinylalcohol with Different Degrees of Saponification

 

SEC_Alpha-3000-Fig53.png

 

Column: TSKgel Alpha-5000 and Alpha-3000, 7.8 mm ID × 30 cm in series
Mobile phase: hexafluoroisopropanol (HFIP)
Flow rate: 0.5 mL/min
Detection: Rl
Temperature: 40 °C
Samples: degree of saponification of polyvinyl alcohol: A. 75% B. 88% C. 100%

 

 

For additional applications, please see our applications database.

 

    

Solvent Compatibility for TSKgel Alpha-3000 for Organic Solvents

 

SEC_Alpha-3000-Fig51.png

Conditions of solvent change

Flow rate: 1.0 mL/min
Temperature: 25 °C
Time for Purge: 8 h

Conditions for TP measurement

Flow rate: 1.0 mL/min 
Detection: RI
Temperature: 25 °C 
Sample: ethylene glycol
 
 
Code #DescriptionLiterature Type
AO01 Gel Filtration Chromatography with TSKgel columns Application Overview
DS1165 TSKgel Alpha-3000 ProductsOperating Conditions and Specifications
IM01 TSKgel Column Instruction ManualInstruction Manual
LCAT01C TSKgel U/HPLC Columns 2019 Product Guide -- SEC, Alpha and SuperAW ColumnsProduct Catalog
PO11 TSKgel Alpha Series Columns for Size Exclusion ChromatographyProduct Overview
SR094 Analyzing Polymers that are Soluble in Polar-Organic Solvents with TSKgel Alpha Series ColumnsSeparation Report
P/NDescriptionParticle Size Housing MaterialID (mm)Length (cm)Price ($) 
0018345TSKgel Alpha-2500-Alpha-M Guard Column for 7.8 mm ID columns13Stainless Steel64789