Products

HPLC Columns

TSKgel SuperHZ3000

TSKgel SuperHZ3000 columns are packed with rigid, porous, 3 μm polymer beads. These ultra-fine particles provide high resolution for the non-aqueous separation of solvent-soluble small molecules and oligomers less than 60,000 Da. The maximum operating temperature for the TSKgel SuperHZ3000 columns are 60 °C.  The THF shipping solvent may be replaced by a limited number of organic solvents.
 
TSKgel SuperHZ3000 columns are ideal for high throughput, high efficiency GPC applications such as those encountered in combinatorial chemistry experiments. These columns feature ultra-low sample adsorption, i.e., the columns show true size exclusion behavior for most polymers.
 
TSKgel SuperHZ3000 column dimensions are 6 mm ID × 15 cm and 4.6 mm ID × 15 cm versus 7.8 mm ID × 30 cm for conventional GPC columns. The smaller column dimensions translate to a reduction of peak volume by a factor of 3.4 (6 mm ID) and a factor of 5.8 (4.6 mm ID) versus the same component eluting from a corresponding TSKgel G3000Hxl column. Thus, your HPLC system may require optimization of components that can give rise to extra-column band broadening, such as connecting tubing, injector, injection volume, detector cell volume, and detector time constant.

 

 

 
P/NDescriptionParticle Size Housing MaterialID (mm)Length (cm)Price ($) 
0019312TSKgel SuperHZ30003Stainless Steel4.6152,149
0019305TSKgel SuperHZ30003Stainless Steel6152,053
                    

Product Attributes

Matrix: polystyrene-divinylbenzene
Particle size (mean): 3 µm
Pore size (mean): 7.5 nm
Exclusion limit: 6.0 × 10Da
Max. temperature: 60 °C

Polystyrene Calibration Curves

SEC_SuperHZ1000-Calibration-Fig80.png

Columns: TSKgel SuperHZ columns,
4.6 mm ID × 15 cm
Mobile phase: THF
Flow rate: 0.35 mL/min
Detection: UV @ 254 nm
Temperature: 25 °C
Injection vol.: 2 µL
Samples: polystyrene standards

           

Comparison of Analysis on TSKgel SuperHZ and TSKgel HXL Columns

 

SEC_SuperHZ2500-Fig82.png

Columns: A: TSKgel SuperHZ columns
(4000, 3000, 2500),
4.6 mm ID × 15 cm ×3
B:TSKgel HXL columns
(4000, 3000, 2500),
7.8 mm ID ×30 cm ×3
Mobile phase: THF
Flow rate: A. 0.35 mL/min  B. 1.0 mL/min
Detection: RI
Temperature: 40 °C
Injection vol.: A. 5 µL  B. 30 µL
Samples: phenolic resin

Code #DescriptionLiterature Type
AN006 High-Throughput GPC Analysis of Phenolic Resin Using TSKgel SuperHZ ColumnsApplication Note
AN054 Analysis of Polymers for Therapeutics Using the EcoSEC GPC System Application Note
AN080 Analysis of Asphalt Binders using Gel Permeation Chromatography Application Note
DS1197 TSKgel SuperHZ3000 ProductsOperating Conditions and Specifications
IM01 TSKgel Column Instruction ManualInstruction Manual
LCAT01D TSKgel U/HPLC Columns 2019 Product Guide -- SEC, H Series ColumnsProduct Catalog
SR101 SuperHZ Series Ultra-High Throughput GPC ColumnsSeparation Report
P/NDescriptionParticle Size Housing MaterialID (mm)Length (cm)Price ($) 
0019314TSKgel SuperHZ1000-4000 and HZM-N and -M Guard Column for 4.6 mm ID columns3Stainless Steel4.62693
0019666TSKgel SuperHZ1000-4000 and HZM-N and -M Guard Column for 6 mm ID columns3Stainless Steel4.63.5693